Constructed of rugged galvanized zinc, Hired-Hand Super Saver XL heaters are ideal for heating swine, poultry and other livestock confinement buildings. These dependable direct-fired gas-circulating heaters are equipped for inside suspension mounting. Natural gas and liquid propane options are available.
Features:
- Hot surface ignition
- Non-vented
- 6 different models to choose from: 40,000 - 250,000 BTUs
- High temp aluminized steel burn chamber
- Swing door for easy access
- Diagnostic light to help troubleshooting
- Comes with standard "Y" heat deflector and 1/2" gas cock, chain kit and sediment trap
- Also available as a High Altitude Heater - 2,000'+
- Outdoor mount heaters available
Available Heaters - NG or LP:
- 75XL LP, QC Part #20500
- 75XL NG, QC Part #20501
- 225XL LP, QC Part #20502
- 225XL NG, QC Part #20503
- 250XL LP, QC Part #20511
- 250XL NG, QC Part #20512
Hired Hand Heater Parts are also available.
Parts
Documents
Q&A
Q: Why does the heater only work for 5 seconds and then stop?
A:
If the heater ignites but shuts down completely after 5 seconds, the control module will have to be replaced. If it ignites and the flame goes out after 5 seconds, then repeats the ignition cycle, there are three possible causes:
- The polarity is reversed on the incoming power supply. All heaters require correct polarity, so make sure power and neutral wires are correct.
- The flame sensor is bad, or no flame is present at the sensor.
- No Earth ground is connected from the power supply.
If you have other questions about this, please give our service department a call at (888) 433-5275
Q: Do you need a vent pipe with QC Part #20500 propane Hired-Hand heater?
A:
This heater does not require a vent pipe. However, it does require a constant exchange of fresh air since it is a non-vented heater. If you are using this in an area that is not well ventilated in this manner, it is best to look at our Modine Heaters (QC Part #20855). If you need help with proper sizing please you can contact our customer service department at (888) 433-5275
Q: If this heater is mounted outside, would it work on a shop building?
A: In dealing with shops/garages we usually recommend an inside unit heater that then vents to the outside.
Ask a question about this product:
Reviews
Write Your Own Review
Customers Also Bought
-
-
- Hired-Hand® Sail Switch$15.14
Don't have an account? Create an account to be able to save items to lists, checkout quicker, and manage your subscriptions!
Log InCreate Account
Or Log In/Sign Up with:
1-888-433-5275
Log in to your Account
Or Log In/Sign Up with:
Create an Account
Already have an account?
Or Log In/Sign Up with:
Log In to Your Account
Don't have an account? Create an account to be able to save items to lists, checkout quicker, and manage your subscriptions!
Log InCreate Account
Or Log In/Sign Up with: