The Phason Staged Environmental Controller - FC-1T-2VAC-3F automatically controls the temperature in a room by operating two variable-speed fans and up to three fixed-stage fans or heaters.

Features: 

  • Two variable cooling stages for controlling fans
  • Three general-purpose relays
  • One alarm relay 
  • Automatic temperature-based control, range: -13 to 125°F
  • Manual override/test mode
  • Seven configurable operating programs
  • Customizable alarm settings
  • Minimum and maximum temperature logging
  • Three-second full-power-turn-on for minimizing fan ice-up
  • Ventilation disable option
  • Power-failure settings protection
  • Four-digit LED display and individual-stage LEDs
  • On-board diagnostics and self-tests
  • Overload protection fuses
  • Temperature sensor; 30 feet, extendable to 500 feet
  • Corrosion, water and fire resistant
  • CSA approval
  • 2-year warranty

Power ratings: 

  • Incoming power
    • 120/230 VAC, 50/60 Hz
  • Variable stages
    • 10A at 120/230 VA, general-purpose (resistive)
    • 7 FLA at 120/230 VAC, PSC motor
    • 1/2 HP at 120 VAC, 1 HP at 230 VAC, PSC motor
  • Variable stage fuses
    • 15A, 250 VAC ABC-type ceramic
  • Relay stages
    • 6A at 120/230 VAC, general purpose (resistive)
    • 1/3 HP at 120 VAC, 1/2 HP at 230 VAC
    • 360 W tungsten at 120 VAC
  • Relay fuses
    • 12A, 250 VAC ABC-type ceramic
  • Alarm relay
    • 0.4A at 125 VAC, 2.0A at 30 VDC, resistive load
    • 0.2A at 125 VAC, 10A at 30 VDC, inductive load
 

Customer Reviews

Based on 1 review
0%
(0)
100%
(1)
0%
(0)
0%
(0)
0%
(0)
A
Anthony Lynch
Great option for swine barn.

So far, so good. Using for a farrowing barn. We have a primary fan, secondary fan, heat mats, and heaters all connected. If this is your setup, I recommend this controller. Everyone is happy and we don't have to manage 4 or 5 different controllers/thermostats, not to mention the cost savings.

Serving agriculturesince 1982

Serving agriculture
since 1982

Over 40 years supporting producers and ag operations

Talk toreal people

Talk to
real people

U.S – based customer service team

Product expertiseyou can use

Product expertise
you can use

Support from people who know the products and how they're used.

U.S owned andoperated

U.S owned and
operated

Proudly based in Schuyler, Nebraska

Straightforwardreturns

Straightforward
returns

Clear policies and support when you need it

Products you've viewed