When you need portable heat from a trusted source, reach for a LB White Tradesman Portable Forced Air Heater. These heaters features a unique 3-trial ignition system, the industry's heaviest gauge combustion chamber and burner plate. These heaters were designed with the harsh environments of the swine industry in mind.
Features
- Dependable electronic spark ignition
- Superior Tri-Shield finish provides extended protection against abrasion and corrosion
- Variable output saves fuel
- 100% test fired at the LB White plant
- Direct fired = 99.97% fuel efficiency
- CSA US and Canada
Tradesman | QC Part #20951 | QC Part #20953 | QC Part #20957 | QC Part #20956 |
---|---|---|---|---|
BTU/H Rating | 70,000-125,000 | 125,000-170,000 | 125,000-155,000 | 250,000-400,000 |
Heated Air Out Put - CFM | 400 | 550 | 550 | 1,050 |
Fuel Type | LP | LP | NG | LP |
Fuel Consumption Min/Max | 3.2 lbs/5.5 hr | 5.8 lbs/7.8 hr | 125 cu.ft./155 hr | 11.6 lbs/18.6 hr |
Inlet Gas Pressure | 11.0 in. w.c. | 11.1 in. w.c. | 7 min/13.5 max in. w.c | 5.5 PSIG |
Amps - Starting/Continuous Operation | 2.0/0.70 | 3.7/1.0 | 3.7/1.0 | 4.0/1.3 |
Dimensions | 25.6" L x 11.8" W x 16.0" H | 24"L x 9.5" W x 16" H | 24" L x 9.5" W x 16" H | 34.5" L x 12.5" W x 21.5" L |
Shipping Weight | 28 lbs | 34 lbs | 34 lbs | 51 lbs |
Case Material | Steel w/Baked Enamel | Steel w/Tri-Shield Coating** | Steel w/Tri-Shield Coating** | Steel w/Tri-Shield Coating** |
High Temp Safety Switch | Yes | Yes | Yes | Yes |
Air Flow Safety Switch | No | No | No | Yes |
Unit Mount Thermostat | No*** | Standard | Standard | Standard |
Gas Hose | Standard | Standard | Optional | Standard |
**Tri-Shield Coating consists of 3 unique protective layers: a non-corrosive hot-dipped galvanized, an oven-cured epoxy primer, and a baked, thermosetting polyester
***Thermostat not available due to configuration of gas train
Heater Mounting: The Tradesman Forced Air Heater should be mounted on a level, stable and noncombustible floor surface. Heater is notrecommended for hanging.
WARNING: Reproductive Harm - https://www.p65warnings.ca.gov
Documents
Q&A
Q: Is electrical power needed?
A: Yes, this heater requires 110V power in order to run the blower and ignition system.
Q: Can a duct be ran on this heater?
A: No, this heater should not be used with any type of ductwork.
Q: What size area can this heat?
A: Heater requirements depend on the area you are heating as well as what you may require for temperature rise in the space. Please contact us with further information.
Ask a question about this product:
Reviews
Write Your Own Review
Customers Also Viewed
Don't have an account? Create an account to be able to save items to lists, checkout quicker, and manage your subscriptions!
Log InCreate Account
Or Log In/Sign Up with:
1-888-433-5275
Log in to your Account
Or Log In/Sign Up with:
Create an Account
Already have an account?
Or Log In/Sign Up with:
Log In to Your Account
Don't have an account? Create an account to be able to save items to lists, checkout quicker, and manage your subscriptions!
Log InCreate Account
Or Log In/Sign Up with: